NextGenX

NextGenx (7)

NextgenX

Fire Equipments and Fire Suppression System

Fire Equipments and Fire Suppression System

NextGenX, an ISO 9001:2015 certified company, with experts who have more than10 years of experience in fire safety field. We’re committed to provide excellent quality of workmanship. Our products are manufactured with the modern state of art unit and In-house testing facilities as per essence of IS/BIS.

The population of the world is rapidly growing and our common life spaces are growing too. It is getting more important to prevent these common spaces from one of the biggest disasters, Fire. We are working with Specialist Engineers and qualified staff in our technical and commercial applications to reduce the fire risk to minimum in living spaces and industrial areas. Our main aim is to give better service, manufacture highly qualified products with our continuously evolving Research & Development. 

Our Products

Wooden Fire Doors

Door Type- Wooden Fire Rated Door

Fire Rating- 60/120 mins

Shutter Thickness- 50mm/55mm

Criteria- Stability, Integrity & with Insulation

Testing Standards- BS 476 Part 20-22. IS 3614 Part2

Frame Size- 120mm x 70mm, 145mm x 70mm

Wooden door frame made out of Hardwood Mirandi Teak/ Teakwood / Ivory coast Teak as per requirement.

Door Shutter - Internal frame made of Hardwood Teak with facing of 3 mm thick commercial ply or veneered ply on both face.

Intumescent fire/smoke seal 20 x 4mm / 15 x 4mm / 10 x 4mm at all three sides of door frame and shutters except bottom.

Wooden Fire Doors - Acoustic

Door Type- Wooden Fire Rated Door

Fire Rating- 120 mins

ShutterThickness- 77mm

Criteria- Stability, Integrity & with Insulation

Testing Standards- BS 476 Part 20-22. IS 3614 Part2

Frame Size- 140mm x 90 mm

Wooden door frame made out of Hardwood Mirandi Teak/ Teakwood / Ivory coast Teak as per requirement.

Door Shutter - Internal frame made of Hardwood Teak with facing of 6 mm thick commercial ply or veneered ply on both face.

Intumescent fire/smoke seal 20 x 4mm / 15 x 4mm / 10 x 4mm at all three sides of door frame and shutters except bottom.

Steel Fire rated Doors

Door Type- Wooden Fire Rated Door

Fire Rating- 60/120 mins

Shutter Thickness- 46mm/50mm

Frame Thickness -1.20 mm/1.60 mm Galvanized Steel

Shutter Sheet Thickness - 0.8/1.0/1.2 mm Galvanized Steel

Criteria- Stability, Integrity & Insulation Material

Testing Standards- BS 476 Part 20-22. IS 3614 Part2

Frame Size- 143mm x 57mm

Steel Fire rated Glazed Doors

Door Type- Glazed Metal Fire Rated door Fixed Partition

Fire Rating- 60/120 mins

Shutter Thickness- 50 mm

Frame Thickness - 1.6 mm Galvanized Steel

Shutter Sheet Thickness - 1.6 mm Galvanized Steel

Glass - 2hrs Fire rated clear glass

Criteria- Stability, Integrity & Insulation Material

Testing Standards- BS 476 Part 20-22. IS 3614 Part2

Steal Lead Lined Door

Door Type- Steel Lead Lined Door

Fire Rating- Not Applicable

Door Thickness- 44mm

Criteria- Nuclear/Radiation Protected

Standards- AERB/DRS

Application- Radiology & Nuclear Medicine

Steel Frame Profile Design - 100X57

Frame Manufactured with 1.2mm GaIvanized Steel

Shutter Thickness - 44 mm

Shutter Infill - Honeycomb/ Mineral Wool InsuIation 2mm lead

Shutter Manufactured with 1mm Galvanised Steel

FHC Doors

Door Frame : 100x80 / 105x80 mm

Door Shutter : 28mm Thick Non Fire Rated (Single Sheeted)

Fixing : Anchor fastener M10 X 100mm

Finish : Powder coated

Vision Panel : 5mm Thick Float Glass

Door Size : 1000x2000 / 1500x2000mm

Sheet Thickness : 1/1.2/1.5 mm

Hose reel Cabinet

Sheet Thickness : 1.2/1.5mm

Door Shutter : 28mm Thick Non Fire Rated (Single Sheeted)

Vision Panel : 5 mm Thick Float Glass

Finish : Powder coating

Size 750 x 600 x 250 mm

Fire Door Standards

Indian/British standard

Labeling is not obligatory.

According to IS/ BS.a fire door can be tested without having leaf on an active latch bolt but with only a self-closing device.

A fire door must be self-closing. Only the active door leaf of an access panel (service ducts) can however be installed without a closer but with a dead lock and a "Fire Door, Keep Shut" sign placed clear on the door face.

Unless shown to be satisfactory when tested as part ofa fire door assembly, the components of any hinge on which the door is hung should be made entirely from materials having a melting point of at least 800 degree C.

If a fire door is held open, it must be equipped with a tested, automatic release mechanism actuated by an automate fire deduction and alarm system ora door-closed delay device.

Two fire doors may be fitted in the same opening so that the total fire resistance in the sum of their individual fire resistance.

Signs and other items of hardware containing plastic should not be fitted on the non-fire side of the metal door or frame.

AMERICANSTANDARD

A fire door must have a label attached indicating the fire test rating.

• Doors are rated for 3/4th of the rating of the surrounding wall.

Every fire door must have the labeled self-latching device to engage the strike. Dead bolts may not be used in place of latch bolts.

A fire door MUST be self closing.

Steel ball bearing hinges must be used. Brass bronze or other bases cannot be used. Plain bearing hinges cannot be used as well.

If a fire door is held open, it must be equipped with a listed/ tested, heat responsive or electromagnetic device, fusible link or a smoke detection device.

Only listed/tested fire door hardware shall be used.

A fire door with glass opening must be provided with a listed/tested glass, a steel frame and glazing bead.

Every assembly configuration such a transom panel, frame material, thickness of metal, leaf construction, core type, door set type (single, double or double egress). etc., must be covered by the test certificate or global assessment report issued by the testing agency.